Process and TEWI analyses formed the basis to develop an air cycle air conditioning system for the ICE3 high speed train. The system is based on a closed-loop overpressure process with two-stage compression and single-stage expansion. The successful test of this system has proven that instead of the vapour cycle air conditioning systems previously applied in trains, air cycle air conditioning systems can also be used effectively.
Details
- Original title: Betriebserfahrungen mit einer Kaltluftklimaanlage im ICE3.
- Record ID : 2002-3188
- Languages: German
- Source: KI Luft Kältetech. - vol. 38 - n. 2
- Publication date: 2002/02
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (3)
See the source
Indexing
-
Trends in railway air conditioning with cold ai...
- Author(s) : MORGENSTERN J., HENATSCH A.
- Date : 1996/05
- Languages : German
- Source: KI Luft Kältetech. - vol. 32 - n. 5
View record
-
Environmentally friendly air cycle air conditio...
- Author(s) : GILES G. R.
- Date : 1999/06
- Languages : English
- Source: AIRAH J. - vol. 53 - n. 6
View record
-
Experience in the development and operation of ...
- Author(s) : KONTCHAKOV E. I., SAMSONOV A. I.
- Date : 2001
- Languages : Russian
- Source: Vestnik Mezdunarodarnoj Akademii Holoda - n. 4
View record
-
Unidad reversible de aire HVAC para trenes públ...
- Author(s) : HAFNER A., FÖRSTERLING S., BO ANDREASSEN H. E., et al.
- Date : 2012/07
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 40
- Formats : PDF
View record
-
Air cycle refrigeration: back to the future? 3.
- Author(s) : FLEMING A. K.
- Date : 1996/01
- Languages : English
- Source: IRHACE J. - vol. 8 - n. 1
View record