Summary
The aim of this paper is to detail an analysis, based on experimental data, of the inter-stage working conditions of a two-stage vapour compression facility equipped with a compound compressor, which operates with the most usual inter-stage configurations (two-stage with direct liquid injection and two-stage with subcooler) in medium- and low-capacity commercial refrigeration applications. The experimental analysis is performed in an evaporating temperature range between -36 and -20°C, and in a condensing temperature range between 30 and 47°C, using one of the fluids most widely-used in Europe for low-temperature applications, the R-404A. The inter-stage working temperature/ pressure obtained in the tests has been contrasted with the two usual criterion of the optimum working conditions definition: the arithmetical mean of the refrigerant condensing and evaporating temperatures and the criterion of equal pressure ratios in both stages. This paper presents the differences and affinities with the criterion and analyses the influence of the intermediate systems (direct liquid injection and subcooler) on the inter-stage operating conditions.
Available documents
Format PDF
Pages: 307-315
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Experimental evaluation of the inter-stage conditions of a two-stage refrigeration cycle using a compound compressor.
- Record ID : 2009-0571
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 2
- Publication date: 2009/03
Links
See other articles in this issue (16)
See the source
Indexing
- Themes: Compression systems
- Keywords: Refrigerating system; R404A; Two-stage system; Compression system; Performance; Expérimentation; Refrigerant
-
Experimental energetic analysis of the subcoole...
- Author(s) : TORRELLA E., LLOPIS R., CABELLO R., et al.
- Date : 2009/05
- Languages : English
- Source: HVAC&R Research - vol. 15 - n. 3
View record
-
Single- or two-stage compression.
- Author(s) : JEKEL T. B., REINDL D. T.
- Date : 2008/08
- Languages : English
- Source: ASHRAE Journal - vol. 50 - n. 8
View record
-
THE USE OF TWO-STAGE RECIPROCATING COMPRESSORS ...
- Author(s) : COSIJN E. A.
- Date : 1989/05
- Languages : Dutch
- Source: Koude Klim./AIRAH J. - vol. 82 - n. 5
View record
-
Tussenkoelers, een 'hot item'.
- Author(s) : BARTHOLOMEUS T. M. C.
- Date : 2006/05
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 99 - n. 5
View record
-
OPTIMUM INTERSTAGE PRESSURE FOR R12 SYSTEM INCL...
- Author(s) : MANOHAR PRASAD, SUDHIR PRASAD
- Date : 1982
- Languages : English
- Source: J. Inst. Eng., India, Mech. Eng. Div. - vol. 63 - n. 3
View record