This work reports on experimental studies using an active magnetic regenerative test apparatus in near room-temperature refrigeration cycles. Experiments using regenerator beds composed of three different magnetocaloric materials combined in a layered configuration with applied fields of 2 T have produced no-load temperature spans in excess of 50 K. The test apparatus uses two active magnetic regenerators each containing approximately 135 g of refrigerant. An overview of the test apparatus, operating parameters, and performance is described. The impacts of operation at varying heat rejection temperatures, applied fields of 1.5 T and frequencies between 0.65 and 1.0 Hz are presented. In addition, the impacts of operating pressure and applied load on temperature spans are discussed.

Available documents

Format PDF

Pages: 1286-1293

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental investigation of a three-material layered active magnetic regenerator.
  • Record ID : 2006-2950
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 29 - n. 8
  • Publication date: 2006/12