Experimental investigation on a thermoacoustic engine having a looped tube and resonator.

Author(s) : YU Z. B., LI Q., CHEN X., et al.

Type of article: Article

Summary

The purpose of this paper is to study the impact of regenerator hydraulic radius, resonator length, and mean pressure on the characteristics of the tested thermoacoustic engine, which has a looped tube and resonator. Two different acoustic oscillations are observed in the tested engine. In this paper, they are called two acoustic modes, high frequency mode (with a frequency independent of the resonator length) and low frequency mode (with a frequency depending on the resonator length). Experimental results indicate that the relative penetration depth (the ratio of penetration depth over hydraulic radius) plays an important role in the excitation and pressure amplitude of the two acoustic modes. For each tested regenerator hydraulic radius, there is a measured optimal relative penetration depth, which leads to the lowest onset temperature difference. Note that, in the tested engine, the measured optimal relative viscous penetration depths are in the range 3-5 (for low frequency mode). Furthermore, experimental results also show that the resonator length affects the presence of high-frequency mode in this engine. [Reprinted with permission from Elsevier. Copyright, 2005].

Details

  • Original title: Experimental investigation on a thermoacoustic engine having a looped tube and resonator.
  • Record ID : 2006-2740
  • Languages: English
  • Source: Cryogenics - vol. 45 - n. 8
  • Publication date: 2005/08

Links


See other articles in this issue (4)
See the source