IIR document

Experimental study of a new double-capillary tube refrigeration system of a chest refrigerator.

Author(s) : SONG X. Z., HE M. G., ZHANG Y., et al.

Summary

A new BCD-192 chest refrigerator with the double-capillary tube in tandem refrigeration cycle has been designed and produced. According to the correlative requirement of the national standard, many experimental researches on the performances of the tandem double-capillary tube refrigeration cycle respectively adopting refrigerant R-12, R-134a and R-600a have been done detailedly. The experiment results show that in contrast to the energy consumptions of the BCD-192 chest refrigerator with the single-capillary refrigeration system, the energy consumptions of the BCD-192 chest refrigerator with the new refrigeration system decrease almost by 8, 7.5 and 8.3%, when refrigerant R-12, R-134a and R-600a are adopted respectively.

Available documents

Format PDF

Pages: ICR07-B2-523

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Experimental study of a new double-capillary tube refrigeration system of a chest refrigerator.
  • Record ID : 2008-0244
  • Languages: English
  • Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Publication date: 2007/08/21

Links


See other articles from the proceedings (839)
See the conference proceedings