Experimental study on frosting control of mobile air conditioning system with microchannel evaporator.

Author(s) : QU X., SHI J., QI Z., et al.

Type of article: Article

Summary

In this paper, a newly developed frost control system is proposed. System bench tests and vehicle test in wind tunnel have been carried out to explore the anti-frosting performance of automotive air conditioning system with microchannel evaporator. The experimental results are compared with the baseline conventional laminated evaporator system. The test results show that the installation position of temperature sensor can dramatically affect the anti-frosting performance. The clutch switching on/off temperature range of the microchannel evaporator is also experimentally studied. The test results show that, with a proper installation position and on/off temperature range, the system COP can be improved, and meanwhile the panel vents’ air off temperature can be reduced, and temperature swing can be reduced. [Reprinted with permission from Elsevier. Copyright, 2011].

Details

  • Original title: Experimental study on frosting control of mobile air conditioning system with microchannel evaporator.
  • Record ID : 30005277
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 31 - n. 14-15
  • Publication date: 2011/10
  • DOI: http://dx.doi.org/10.1016/j.applthermaleng.2011.04.051

Links


See other articles in this issue (21)
See the source