IIR document

Factors contributing to refrigerator cycling losses.

Author(s) : RUBAS P. J., BULLARD C. W.

Type of article: Article, IJR article

Summary

Oil solubility, refrigerant migration, and redistribution are three factors affecting the transient and cycling performance of all refrigeration and air-conditioning equipment. These effects are quantified for a refrigerator instrumented with immersion thermocouples, pressure transducers, and microphones. The analytical methods, however, are applicable to other types of refrigeration and air-conditioning systems, including those with capillary tube/suction line heat exchangers.

Available documents

Format PDF

Pages: 168-176

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Factors contributing to refrigerator cycling losses.
  • Record ID : 1995-3535
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 18 - n. 3
  • Publication date: 1995/03