IIR document
Field measurement on rooftop condensing unit before and after reconstruction.
Number: 0366
Author(s) : TOMLEIN P.
Summary
Packaged rooftops cooling only (hereinafter referred to as rooftop) equipped with AC fans motors on condensing unit can be retrofitted to fans with EC motors. Economy of fan retrofits depends on operation time, which is short in cooling mode. Reconstruction of rooftops from cooling-only to heating-also mode enables longer operation time and better retrofit and reconstruction economy. Methodology for heat balance calculation in cooling and heating mode can differ. Monthly method according to STN EN ISO 13790 and hourly method according to EN ISO 52016-1 were used to calculate thermal balances of the building. Importance of the new hourly method is demonstrated in comparison with the commonly used monthly method. Efficiency and operation time of the heat pump depended on on/off compressors, which operation range had to be limited. Field measurement showed higher efficiency after fans retrofit. Efficiency of reconstruction from cooling-only to heating-also mode depends on the extent of reconstruction. Field measurement showed a need for precautions against possibly risky compressor operation.
Available documents
Format PDF
Pages: 9
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Field measurement on rooftop condensing unit before and after reconstruction.
- Record ID : 30028225
- Languages: English
- Subject: Technology
- Source: 10th IIR Conference on Compressors and Refrigerants.
- Publication date: 2021/01/13
- DOI: http://dx.doi.org/10.18462/iir.compr.2021.0366
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (35)
See the conference proceedings
Indexing
-
Improved calculation of air distribution in an ...
- Author(s) : TARNOPOLSKY M.
- Date : 1994
- Languages : English
- Source: ASHRAE Transactions 1994.
View record
-
Uniformity of Supply Air in the Plenum for Unde...
- Author(s) : FAN X., YU T., LIU P., LI X.
- Date : 2022/09
- Languages : English
- Source: Energies - vol. 15 - n. 17
- Formats : PDF
View record
-
Ventilation of an auditorium and its effect on ...
- Author(s) : VAZQUEZ B., SAMANO D., YIANNESKIS M.
- Date : 1993/11/01
- Languages : English
View record
-
INTEGRATED DAYLIGHTING, HEATING, AND COOLING MO...
- Author(s) : DEGELMAN L. O., MOLINELLI J. F. Jr, KIM K. S.
- Date : 1988
- Languages : English
View record
-
Study on the smart operation approach of an air...
- Author(s) : YOON M. S., YOON W. S.
- Date : 2021/08/31
- Languages : English
- Source: 13th IEA Heat Pump Conference 2021: Heat Pumps – Mission for the Green World. Conference proceedings [full papers]
- Formats : PDF
View record