Flow regime identification in cryogenic gas-liquid flow through vertical tubes.

Author(s) : DAS R., PATTANAYAK S.

Type of article: Article

Summary

A small capacitor is used to sense the local void fraction of the flowing mixture. This technique has been used principally to overcome difficulties in detecting the fractional change of a very small capacitance of the void fraction sensor used in monitoring gas-liquid two-phase flow of nitrogen.

Details

  • Original title: Flow regime identification in cryogenic gas-liquid flow through vertical tubes.
  • Record ID : 1996-1366
  • Languages: English
  • Source: Cryogenics - vol. 35 - n. 6
  • Publication date: 1995/06