Going beyond the stars: the Queensland Cairns Government Office Building, William McCormack Place is already an ABGR 5-Star building but how can it be improved, i.e. 5-star+.
Author(s) : MCGREGOR P., STANDFIELD G.
Summary
The Queensland Cairns Government Office Building, the William McCormack Place was designed to be an ABGR 4-Star building. In operation it has achieved a certified ABGR rating of 5 Stars. The air conditioning installed in William McCormack Place is designed for a tropical location wherein the tasks for treating the room and ventilation loads are separated, i.e. the humid outside air is conditioned by an outside air pre-conditioning system thereby allowing the distributed space air handling units to condition the internal loads that are primarily sensible heat. The existing pre-conditioner comprises a rotary enthalpy wheel heat-exchanger and a 152 kW chilled water cooling coil. This study is intended to review the outside air pre-conditioner and show that an alternative system can provide similar outside air supply conditions with a substantially reduced 74 kW chilled water cooling coil.
Details
- Original title: Going beyond the stars: the Queensland Cairns Government Office Building, William McCormack Place is already an ABGR 5-Star building but how can it be improved, i.e. 5-star+.
- Record ID : 2010-1575
- Languages: English
- Source: AIRAH sustainability conference for tropical and subtropical climates.
- Publication date: 2006/09/14
Links
See other articles from the proceedings (3)
See the conference proceedings
Indexing
-
Displacement diffuser for use in tropical clima...
- Author(s) : DRINIC Z.
- Date : 2006/09/14
- Languages : English
- Source: AIRAH sustainability conference for tropical and subtropical climates.
View record
-
Displacement ventilation in warm climates.
- Author(s) : SKISTAD H.
- Date : 2002/03/07
- Languages : English
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
View record
-
Indoor humidity modelling and evaluation of con...
- Author(s) : LUCAS F., MIRANVILLE F.
- Date : 2004
- Languages : English
- Source: ASHRAE Transactions. 2004 Annual Meeting, Nashville, Tennessee, USA. Volume 110, part 2 + CD-ROM.
View record
-
Using wind as an approach natural ventilation i...
- Author(s) : KARIMZADEH A., SHAHRIARI S., SHAHRIARI S. K. A.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Optimisation of passive ventilation design for ...
- Author(s) : GROENHOUT N., PARTRIDGE L.
- Date : 2006/09/14
- Languages : English
- Source: AIRAH sustainability conference for tropical and subtropical climates.
View record