Heat exchange during refrigerant R22 boiling inside horizontal tubes.

Summary

The experiments were carried out with a heat flux of 5-15 kilowatts per m2, a mass flux of 90-450 kg per m2 second, vapour quality in cross sections of 0.05-0.7. The results of this heat transfer investigation with refrigerant R22 boiling in a smooth tube were compared with relations of Kandlikar, Steiner and Hihara.

Details

  • Original title: Heat exchange during refrigerant R22 boiling inside horizontal tubes.
  • Record ID : 2000-0125
  • Languages: English
  • Source: Heat transfer in condensation and evaporation: application to industrial and environmental processes. Preprints of the EUROTHERM Seminar 62.
  • Publication date: 1998/11/17
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (34)
See the conference proceedings