HEAT PUMP SETBACK: COMPUTER PREDICTION AND FIELD TEST VERIFICATION OF ENERGY SAVINGS WITH IMPROVED CONTROL.
Author(s) : BENTON R.
Summary
A THERMOSTAT WAS DESIGNED WITH AN IMPROVED CONTROL STRATEGY THAT REDUCES OR ELIMINATES THE USE OF AUXILIARY HEAT FOR RECOVERY. PERCENTAGE ENERGY SAVINGS APPEAR TO BE AS LARGE OR LARGER THAN THOSE FOR CONVENTIONAL FOSSIL-FUEL AND ELECTRIC SYSTEMS. THE PURPOSE OF THIS PAPER IS TO DESCRIBE HOW THIS THERMOSTAT WAS DEVELOPED, HOW IT WORKS, AND WHY THERE IS CONFIDENCE THAT IT WILL BE COST-EFFECTIVE.
Details
- Original title: HEAT PUMP SETBACK: COMPUTER PREDICTION AND FIELD TEST VERIFICATION OF ENERGY SAVINGS WITH IMPROVED CONTROL.
- Record ID : 1984-2020
- Languages: English
- Publication date: 1983
- Source: Source: ASHRAE Trans.
vol. 89; n. 1B; 716-734; 16 fig.; 5 tabl.; 10 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
-
IMPROVEMENTS OF THE COP FOR SMALL HEAT PUMPS BY...
- Author(s) : FORDSMAND M.
- Date : 1983/08/07
- Languages : English
- Source: [Refrigeration serving humanity]. Proceedings of the XVIth international Congress of Refrigeration.
- Formats : PDF
View record
-
RULE-BASED THERMOSTAT DESIGN FOR NIGHT SETBACK ...
- Author(s) : RUTZ A. L., MORAN M. J.
- Date : 1990
- Languages : English
- Source: Energy, Int. J. - vol. 15 - n. 11
View record
-
IMPROVEMENTS IN CONTROLLED ENVIRONMENT FACILITI...
- Author(s) : ROSELL J.
- Date : 1983/01
- Languages : English
- Source: Int. J. Energy Res. - vol. 7
View record
-
MEASUREMENT AND CONTROL IN HEATING AND AIR COND...
- Author(s) : KOTZ H. J., AREND H. O., TELENSKY H.
- Date : 1983
- Languages : German
- Source: Elektrowärme int., A - n. 5
View record
-
HEAT PUMP SETBACK: COMPUTER PREDICTION AND FIEL...
- Author(s) : BENTON R.
- Date : 1982/12
- Languages : English
- Source: ASHRAE Journal - vol. 24 - n. 12
View record