Impact of using cool paints on energy demand and thermal comfort of a residential building.
Author(s) : DIAS D., MACHADO J., LEAL V., et al.
Type of article: Article, Case study
Summary
This work studies the impact of using cool paints and/or thermal insulation on the thermal behavior and energy demand of a residential building. Buildings with thermal characteristics representing both old and new constructions are considered. The results were obtained using the dynamic computer simulator ESP-r. Recommendations for designers and/or house-owners in terms of deciding the best thermal comfort solution are withdrawn. For a case-study building in Portugal, in the summer, it was found that an increase in roof and façade value of total solar reflectance (TSR) from 50% to 92% reduced the maximum indoor free-float temperature between 2.0°C and 4.7°C in old construction (without thermal insulation), and between 1.2°C and 3.0°C in new construction (with thermal insulation). This had as a trade-off effect the decrease of the minimum indoor temperature of up to 1.5°C. The results of annual energy demand for heating showed a maximum penalty of about 30% when using cool paints. However, it was demonstrated that the cooling demand almost vanishes, eliminating the need to install air-conditioning devices. The analysis of specific real hot weather time periods showed that the maximum altitude of the sun, which is related to the month of the year, determines the solution that originates the highest temperature reduction. As the maximum sun altitude decreases the cool paints show comparatively better results.
Details
- Original title: Impact of using cool paints on energy demand and thermal comfort of a residential building.
- Record ID : 30011044
- Languages: English
- Source: Applied Thermal Engineering - vol. 65 - n. 1-2
- Publication date: 2014/04
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.12.056
Links
See other articles in this issue (18)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Energy consumption; Portugal; Painting; Residential building; Case study; Insulation; Thermal comfort
-
Multi-objective optimization model for building...
- Author(s) : ASADI E., GAMEIRO DA SILVA M., HENGGELER ANTUNES C., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Appartementen Assen duurzaam verwarmd én gekoeld.
- Date : 2007/06
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 100 - n. 5
View record
-
Analysis on operation characteristics of air co...
- Author(s) : DING Y., LIU X., TANG H.
- Date : 2016
- Languages : English
View record
-
Linking Indoor Thermal Comfort with Climate, En...
- Author(s) : DELGADO J., MATOS A. M., GUIMARÃES A. S.
- Date : 2022/08
- Languages : English
- Source: Energies - vol. 15 - n. 16
- Formats : PDF
View record
-
Total building commissioning: case study of the...
- Author(s) : SETTY B. S.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record