Summary
This paper presents an experimental investigation on the heating performance of a residential air conditioner with a vapor-bypassed evaporator. The vapor-bypassed evaporator, in which a phase separator is set in the middle of the refrigerant circuit to bypass vapor refrigerant, can reduce the refrigerant pressure drop and enhance the heat transfer coefficient at refrigerant side. The tested system contains two operation modes, i.e., vapor-bypassed (VB) mode and conventional heat pump (CH) mode. It is indicated that as the heating capacity ranges 1,800~4,800 W, the COP of VB mode is improved 3.2%~11% over CH mode under conventional heating condition. Under low-temperature heating condition (frosting condition), the system at VB mode yields 16.1% higher average integral heating capacity and 5% higher COP over CH mode at a fixed compressor frequency of 100 Hz. In conclusion, using the vapor-bypassed evaporator is a promising way for enhancing the heating performance of an air conditioner.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Improving the heating performance of a residential air conditioner by using a vapor-bypassed evaporator.
- Record ID : 30026630
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.0492
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
-
Accelerating-particle-deposition method for qui...
- Author(s) : ZHUANG D., DING G., YANG Y., et al.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Evaluation the effect of washing on the heat tr...
- Author(s) : MEHRABI M., YUILL D.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Effect of louver angle on performance of heat e...
- Author(s) : HRNJAK P.
- Date : 2017/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 84
- Formats : PDF
View record
-
Development of flat tube heat exchanger for hea...
- Author(s) : MATSUDA T., ISHIBASHI A., OKAZAKI T., et al.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Application of ø5mm diameter tube heat exchange...
- Author(s) : WANG L., LIU Z., CAO Y., et al.
- Date : 2014/03
- Languages : Chinese
- Source: Refrigeration - vol. 33 - n. 3
View record