IIR document

Investigation of refrigerant pipe pressure drop and charge reduction of mobile air conditioning units with R1234yf.

Author(s) : MEINERT R., SPEERFORCK A.

Type of article: IJR article

Summary

In this study, the pressure drop of automotive refrigerant pipes with the refrigerant R1234yf is investigated in detail. For this purpose, 1D and 3D simulations are compared with respect to prediction accuracy using liquid lines from a production car. It is shown that for a combined approach of the methods a very good agreement with the measured values can be obtained, whereas simplified modeling of the line as a straight pipe of equal length significantly underestimates the experimental values. The transition pieces between the pipe and the hose are of particular importance, since they account for up to 85 % of the total pressure drop and therefore result in major errors if neglected. If hoses were eliminated, the lines could be designed smaller, resulting in a charge reduction of up to 56 %.

Available documents

Format PDF

Pages: 442-451

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Investigation of refrigerant pipe pressure drop and charge reduction of mobile air conditioning units with R1234yf.
  • Record ID : 30030923
  • Languages: English
  • Subject: Technology
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 146
  • Publication date: 2023/02
  • DOI: http://dx.doi.org/10.1016/j.ijrefrig.2022.12.005

Links


See other articles in this issue (41)
See the source