INVESTIGATIONS ON COOLING WITH FORCED FLOW OF HELIUM II. 2.
Author(s) : SRINIVASAN R., HOFMANN A.
Type of article: Article
Summary
THE MEASUREMENTS DESCRIBED IN PART 1 OF THE PAPER HAVE BEEN EXTENDED TO A PRESSURE OF 700 KILOPASCALS. THE VALUE OF THE CONDUCTIVITY FUNCTION, F(T), AT A TEMPERATURE GREATER THAN TMAX , AT WHICH IT EXHIBITS A MAXIMUM, DROPS RAPIDLY WITH INCREASING PRESSURE. BELOW TMAX THE CHANGE IN F(T) WITH PRESSURE IS LESS DRASTIC. THE GORTER-MELLINK CONSTANT INCREASES LINEARLY WITH PRESSURE IN THE RANGE 1.5-2 K AND ITS PRESSURE COEFFICIENT AT 100 KILOPASCALS IS 0.038 MORE OR LESS 0.01 PER 100 KILOPASCALS, INDEPENDENT OF TEMPERATURE. THE SUPERFILTER IS TESTED AT 1.8 K. THE FLOW THROUGH THE SUPERFILTER IS GORTER-MELLINK FLOW.
Details
- Original title: INVESTIGATIONS ON COOLING WITH FORCED FLOW OF HELIUM II. 2.
- Record ID : 1986-2155
- Languages: English
- Source: Cryogenics - vol. 25 - n. 11
- Publication date: 1985
Links
See other articles in this issue (4)
See the source
Indexing
-
A study of the thermal conductivity of composit...
- Author(s) : WANG H. L., WU T. H., GUO F. Z.
- Date : 1994
- Languages : English
- Source: Physica, B - n. 194-196
View record
-
HEAT FLUX DENSITY IN OPEN HELIUM II-COOLED CHAN...
- Author(s) : PRONKO V. G.
- Date : 1981/11/16
- Languages : English
- Source: Stability of superconductors.
- Formats : PDF
View record
-
Kapitza resistance and thermal conductivity of ...
- Author(s) : HATTENBERGER G., CARRÉ S., JUSTER F. P., et al.
- Date : 2005/06
- Languages : English
- Source: Cryogenics - vol. 45 - n. 6
View record
-
Heat flow measurements of superfluid helium 4 i...
- Author(s) : FUJII Y., SAKAI K., OGURA M.
- Date : 1993/10
- Languages : English
- Source: Cryogenics - vol. 33 - n. 10
View record
-
EXPERIMENTAL STUDY OF THE CRITICAL DENSITY OF H...
- Author(s) : PRON'KO V. G., GOROKHOV V. V., SAVERIN V. N.
- Date : 1981
- Languages : Russian
- Source: Inzh.-fiz. Zh. - vol. 41 - n. 3
View record