Leakage rates and measuring of concentration gradients in flammable fluids.
Débits de fuite et mesures de gradients de concentration de fluides inflammables.
Author(s) : CLODIC D.
Summary
The energy-research centre of the Ecole des Mines in Paris carried out two series of tests on propane and isobutane in a specialised laboratory, the National Center for Prevention and Protection. The results of these tests have been presented in two publications. The main findings are as follows: concentrations greater than the lower limit of flammability were measured at ground level for quantities of fluid dissimenated into the room that were much lower than the practical limits set by safety standards (ie, ASHRAE 15 and pr-EN 378). When lit up, the fluid produced rapid spread of flames at ground-level, while leaks inside a freezer created reproducible balls of fire.
Details
- Original title: Débits de fuite et mesures de gradients de concentration de fluides inflammables.
- Record ID : 1998-0096
- Languages: French
- Source: Journée technique Pôle Fluides Frigorigènes. Rapport d'étude.
- Publication date: 1997/02/07
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (4)
See the conference proceedings
Indexing
- Themes: Hydrocarbons
- Keywords: Isobutane; Measurement; Propane; Flammability; Hydrocarbon; Testing; Refrigerant
-
An experimental investigation of the flammabili...
- Author(s) : LI Y., TONG M.
- Date : 2002/09/17
- Languages : English
- Formats : PDF
View record
-
Leak flow rates and measurements of concentrati...
- Author(s) : CLODIC D.
- Date : 1997/04/18
- Languages : English
- Source: FREE '97. Fluidi refrigeranti, espandenti, estinguenti./ FREE '97. Refrigerating, blowing and extinguishing agents.
View record
-
Experimental results of the safety tests on dom...
- Author(s) : IZ H., YILMAZ T., TANES Y.
- Date : 1996/09/03
- Languages : English
- Source: Applications for Natural Refrigerants
- Formats : PDF
View record
-
Impact of hydrocarbon refrigerants type on leak...
- Author(s) : ESMAEELIAN J., KHODABANDEH R., PALM B., IGNATOWICZ M.
- Date : 2024/09
- Languages : English
- Source: 11th IIR Conference on Compressors and Refrigerants.
- Formats : PDF
View record
-
Calorimeter for measuring the isobaric specific...
- Author(s) : TANAKA K., TAKAHASHI G., KITAYAMA A., et al.
- Date : 2008/09/07
- Languages : English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
View record