LIQUID-VAPOUR BALANCE. TEST PLANT AND METER READINGS FOR AN R12-R11 MIXTURE.
[In German. / En allemand.]
Author(s) : LOI N. D.
Type of article: Article
Summary
A DESCRIPTION IS GIVEN OF A DETECTOR WITH TEST PLANT ON THE STATIC MEASURING PRINCIPLE FOR THE DETERMINATION OF LIQUID-VAPOUR PHASE BALANCES OF HALOGENATED REFRIGERANT MIXTURES RANGING FROM 253 TO 363 K (-20 TO 90 DEG C) AND FROM 0.02 TO 5 MPA. THE HORIZONTAL ARRANGEMENT OF THE DETECTOR AND STIRRER AS WELL AS A HAND-OPERATED PISTON PUMP ENABLE ACCURATE BALANCE DATA WITH LITTLE MATERIAL AND IN A SHORT TIME TO BE GAINED. MEASURED VALUES FOR THE R12/R 11 MIXTURE ARE GIVEN AND COMPARED WITH SOME PUBLICATIONS.
Details
- Original title: [In German. / En allemand.]
- Record ID : 1983-2101
- Languages: German
- Publication date: 1983
- Source: Source: Luft Kältetech.
vol. 19; n. 1; 37-40; 3 fig.; 1 tabl.; 14 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
-
Themes:
CFCs;
Blends - Keywords: Halogen; Liquid-vapour; R12; R11; Mixture; Refrigerant
-
THE EFFECT OF HEAT REGENERATION IN REFRIGERATIN...
- Author(s) : ZAKRZEWSKI B.
- Date : 1983
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 6 - n. 2
- Formats : PDF
View record
-
VAPOUR-LIQUID EQUILIBRIA OF SOME HALOGENATED HY...
- Author(s) : NAKAIWA M.
- Date : 1987/08/24
- Languages : English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
RECOVERY OF CFC REFRIGERANTS DURING SERVICE AND...
- Author(s) : MANZ K. W.
- Date : 1988
- Languages : English
View record
-
CRITICAL PARAMETERS OF REFRIGERANT MIXTURES.
- Author(s) : KASATSCHKI G. S.
- Date : 1984
- Languages : German
View record
-
HOW INDUSTRY IS REDUCING DEPENDENCE ON OZONE-DE...
- Date : 1988/06
- Languages : English
- Source: EPA, Status Rep. - 25 p.; 3 fig.
View record