Summary
In order to improve the energy efficiency of traditional room air conditioners, this paper presented the heat pipe combined evaporative cooling room air conditioner. This study built the mathematical model and carried out programming to make simulation analysis on the annual dynamical operating performance of the heat pipe combined evaporative cooling room air conditioner under different area parameters of heat exchangers, and then took into account the economic factors, to obtain that the optimal areas of evaporator and condenser were respectively 14.89 m2 and 23.07 m2. In addition, based on the optimal areas, it was concluded that the COP of the combined room air conditioner increased by 33.27%, and energy consumption reduced by 32.83%, comparing with traditional air conditioner, which didn’t include evaporative cooling technology and separate type heat pipe technology.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Optimal design of heat exchangers of the heat pipe combined evaporative cooling room air conditioner.
- Record ID : 30015757
- Languages: English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0183
Links
See other articles from the proceedings (657)
See the conference proceedings
-
Choice of the optimal construction of a regener...
- Author(s) : GARANOV S. A., PANTELEEV D. A., SOKOLIK A. N.
- Date : 2015/10
- Languages : Russian
- Source: Kholodilnaya Tekhnika - n. 10
View record
-
Energy efficiency analysis between air cooling ...
- Author(s) : WANG Q., PENG S., DING Q.
- Date : 2014/07
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 292
- Formats : PDF
View record
-
Development of 20 IEER rooftop units: a simulat...
- Author(s) : SHEN B., RICE C. K., VINEYARD E. A.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Control method of a cooling apparatus in low ou...
- Author(s) : NAKAO M., UEKUSA T., KAWAI S.
- Date : 1995/10
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 59
View record
-
Clean room energy efficiency.
- Author(s) : MATHEW P. A., TSCHUDI W., SARTOR D., et al.
- Date : 2010/10
- Languages : English
- Source: ASHRAE Journal - vol. 52 - n. 10
View record