Summary
The pumped loop heat pipe heat exchanger unit for cooling consumes low power and has a high coefficient of performance (EER). For optimization applications at small data centers, this paper investigated the operating performance of the pumped loop heat pipe heat exchanger unit used in a small data center. The EER under different outdoor temperatures was analyzed, and the fitted operating characteristic curve showed that EER varied with outdoor temperature. An energy saving analysis was done with the fitting curve, and the total energy consumption was calculated at each temperature interval in Beijing. The results show that in transitional and winter season, when the outdoor temperature is below 15°C, the pumped loop heat pipe heat exchanger unit can be turned on to bear part or total thermal load and performs well in energy saving. Compared to the air conditioning and refrigeration system for cooling, the energy saving can reach at least 35.76%.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Application investigation on a pumped loop heat pipe heat exchanger unit for a small data center.
- Record ID : 30015342
- Languages: English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0175
Links
See other articles from the proceedings (657)
See the conference proceedings
-
Evaporative cooling choices to maximize watersi...
- Author(s) : LANE J., CLINE D.
- Date : 2008/01/19
- Languages : English
- Source: ASHRAE Transactions. 2008 Winter Meeting, New York City, NY. Volume 114, part 1 + CD-ROM.
View record
-
Net-zero energy data center.
- Author(s) : PETERSON J.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
An integrated chiller using magnetic-bearing co...
- Author(s) : ZHANG P., SHI W., WANG B., et al.
- Date : 2015/08/16
- Languages : English
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
View record
-
Energy-saving potential study on telecommunicat...
- Author(s) : ZHOU F., CHEN J., MA G. Y., et al.
- Date : 2012/07/16
- Languages : English
- Source: 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
View record
-
Cooling technologies in datacom facilities: An ...
- Author(s) : ISAZADEH A., ZIVIANI D., CLARIDGE D. E.
- Date : 2022
- Languages : English
- Source: 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record