Recharge demand mitigation for latent heat thermal energy storage at off-peak hours.
Number: 3255
Author(s) : OTHMAN H. A. al-, AUTE V., TANCABEL J.
Summary
The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharing may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.
Available documents
Format PDF
Pages: 10 p.
Available
Free
Details
- Original title: Recharge demand mitigation for latent heat thermal energy storage at off-peak hours.
- Record ID : 30032945
- Languages: English
- Source: 2024 Purdue Conferences. 8th International High Performance Buildings Conference at Purdue.
- Publication date: 2024/07/15
Links
See other articles from the proceedings (63)
See the conference proceedings
Indexing
-
Descripción y análisis del uso de un depósito d...
- Author(s) : REAL FERNÁNDEZ A., NAVARRO-ESBRÍ J., BARRAGÁN-CERVERA A., et al.
- Date : 2016/05/03
- Languages : Spanish
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record
-
Validation of a Resistance-Capacitance Model (R...
- Author(s) : GUARDA D., MARTELLETTO F., RIGHETTI G., DORETTI L., ZILIO C., MANCIN S.
- Date : 2024/05/31
- Languages : English
- Source: 14th IIR Conference on Phase-Change Materials and Slurries for Refrigeration and Air Conditioning. Proceedings: Paris France, May 29-31, 2024.
- Formats : PDF
View record
-
Effect of metal foam integration on the thermal...
- Author(s) : KOTB A., WANG S.
- Date : 2022
- Languages : English
- Source: 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Salt hydrate eutectic mixtures for near-ambient...
- Author(s) : AKAMO D., TURNAOGLU T., LACLAIR T. J., GLUESENKAMP K. R., GOSWANI M., RIOS O., HIRSCHEY J.
- Date : 2022
- Languages : English
- Source: 2022 Purdue Conferences. 19th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
TBAB hydrate slurry based latent heat thermal s...
- Author(s) : ZHOU H., INFANTE FERREIRA C.
- Date : 2016/05/18
- Languages : English
- Source: 11th IIR Conference on Phase-Change Materials and Slurries for Refrigeration and Air Conditioning. Proceedings: Karlsruhe, Germany, May 18-20, 2016.
- Formats : PDF
View record