Research on the application of rotary compressor with two independent suction pressures on fresh air-conditioning system.

Number: pap. 1230

Author(s) : ZHANG L., LIU C.

Summary

A rotary compressor with double cylinders, double suctions and double reservoirs is presented in this paper. The two cylinders achieve independent suction pressures and two different evaporation temperatures. Combined with the structure characteristics of the rotary compressor with two independent suction pressures and the operation characteristics of the household fresh air conditioning system, the compressor can be applied to the household fresh air conditioning system with two evaporating temperatures. By comparison, the theoretical circulation COP of the new fresh system applying the compressor with two independent suction pressures is about 23% higher than that of the fresh air conditioning system with conventional compressor. By test verification, the COP of the fresh air conditioning system with the compressor with two independent suction pressures is increased by 6.55%.

Available documents

Format PDF

Pages: 8

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Research on the application of rotary compressor with two independent suction pressures on fresh air-conditioning system.
  • Record ID : 30024255
  • Languages: English
  • Source: 2018 Purdue Conferences. 24th International Compressor Engineering Conference at Purdue.
  • Publication date: 2018/07/09

Links


See other articles from the proceedings (130)
See the conference proceedings