IIR document
SCOP experimental comparison of refrigerants R454B and R410A in a domestic heat pump.
Number: 0655
Author(s) : ORTEGA I., SIERES J., CERDEIRA F., SANTOS J. M., ALVAREZ E.
Summary
410A is a widely used refrigerant in commercial heat pump units. The Global Warming Potential (GWP) of R410A is 1924, so lower GWP alternatives such as R454B are being proposed. R454B is a mildly flammable refrigerant with a GWP of 466.
In this paper, we present and analyze the results of the seasonal coefficient of performance (SCOP) of a domestic brine‐to‐water heat pump with the refrigerants R410A and R454B. The main components of the heat pump are a variable speed scroll type compressor, two brazed plate heat exchangers (condenser and evaporator) and an electronic expansion valve. The part load testing conditions and the calculation methods to determine the SCOP are based on the EN 14825:2018 standard. Results show that for the same design heating load, the SCOP of R454B is about 1.5% higher than for R410A.
Available documents
Format PDF
Pages: 11
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: SCOP experimental comparison of refrigerants R454B and R410A in a domestic heat pump.
- Record ID : 30031818
- Languages: English
- Subject: Technology, HFCs alternatives
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Publication date: 2023/08/21
- DOI: http://dx.doi.org/10.18462/iir.icr.2023.0655
Links
See other articles from the proceedings (491)
See the conference proceedings
Indexing
-
Themes:
Residential heat-pumps;
HFO et HCFO - Keywords: Low GWP; Domestic heat pump; Seasonal performance; COP; Expérimentation; Energy consumption; R410A; R454B
-
Seasonal energy performance evaluation of a geo...
- Author(s) : SANTOS J. M., SIERES J., ORTEGA I., CERDEIRA F., ALVAREZ E.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Low GWP HFO Refrigerants for extended temperatu...
- Author(s) : CHRISTMANN J. M., CODELLA F., KÜPPER H. D., SAAB S.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Numerical modelling and seasonal performance an...
- Author(s) : DONGELLINI M., NALDI C., SIANI R., MORINI G. L.
- Date : 2021/09/01
- Languages : English
- Source: 6th IIR Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
View record
-
Evaluation of lower GWP alternatives to R410A i...
- Author(s) : PETERSEN M., KUJAK S., NAYAK G.
- Date : 2023/05/15
- Languages : English
- Source: 14th IEA Heat Pump Conference 2023, Chicago, Illinois.
- Formats : PDF
View record
-
Thermal conductivity measurement of HFO/HFC mix...
- Author(s) : MIZUNO S., TUHIN A. R., KARIYA K., MIYARA A.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record