IIR document
Semi-hermetic reciprocating and screw compressors for carbon dioxide cascade systems.
Author(s) : RENZ H.
Summary
In comparison to conventional low temperature applications, a particularly high volumetric refrigeration capacity allows significant cost reductions in compressors and pipe-work. Even for larger capacities, this results in a potential use of compressor sizes usually found in commercial and light industrial applications. On the other hand, high operating and standstill pressures demand special criteria for compressor design and protection measures. This presentation deals with possible solutions in system layout. Protection measures and performance behaviour versus conventional plant designs, as well as lubricants are reviewed.
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Semi-hermetic reciprocating and screw compressors for carbon dioxide cascade systems.
- Record ID : 2000-1220
- Languages: English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Publication date: 1999/09/19
Links
See other articles from the proceedings (447)
See the conference proceedings
Indexing
-
Themes:
Compression systems;
CO2 - Keywords: Refrigerating system; Compression system; Cascade system; Refrigerant; CO2
-
Plant design considerations for cascade systems...
- Author(s) : ROLFSMAN L.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Performance testing and comparison of liquid ov...
- Author(s) : REES B., ROHRER C., SHAPIRO D., et al.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Cascade systems: past, present, and future.
- Author(s) : BANSAL P. K., JAIN S.
- Date : 2007/01/27
- Languages : English
- Source: ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
View record
-
Carbon dioxide as refrigerant: why and when ben...
- Author(s) : KOSTER G. J.
- Date : 2005/05/06
- Languages : English
- Source: Ammonia Refrigerating Systems, Renewal and Improvement.
- Formats : PDF
View record
-
CO2 used as low temperature refrigerant in ammo...
- Author(s) : VESTERGAARD N. P.
- Date : 2005/05/06
- Languages : English
- Source: Ammonia Refrigerating Systems, Renewal and Improvement.
- Formats : PDF
View record