Summary
THE EXPERIMENT WAS CARRIED OUT USING A ONE HORSEPOWER (0.75 KILOW) HEAT PUMP, AND THE ENERGY BALANCE DURING DEFROSTING WAS ANALYZED. THE FOLLOWING METHODS ARE EFFECTIVE TO SHORTEN THE DEFROSTING TIME: (1) INCREASE IN POWER INPUT TO THE COMPRESSOR DURING DEFROSTING, (2) UTILIZATION OF THE COMPRESSOR FOR ENERGY STORAGE, AND (3) REDUCTION OF THE WATER LEFT ON THE OUTDOOR HEAT EXCHANGER. A HEAT PUMP WITH THE NEW DEFROSTING SYSTEM WAS CONSTRUCTED. ITS DEFROST TIME WAS 1 MINUTE AND 55 SECONDS AND THAT OF A CONVENTIONAL HEAT PUMP ABOUT 4 OR 5 MINUTES.
Details
- Original title: SHORTENING THE DEFROST TIME ON A HEAT PUMP AIR CONDITIONER.
- Record ID : 1987-1947
- Languages: English
- Publication date: 1986
- Source: Source: ASHRAE Trans.
vol. 92; n. 2A; 20-29; 10 fig.; 5 tabl.; 1 ref. - Document available for consultation in the library of the IIR headquarters only.
Indexing
- Themes: Heat pumps, energy recovery: general information
- Keywords: Air conditioner; Air; Heat pump; Performance; Defrosting
-
MEASUREMENT OF REFRIGERANT LEAKAGE IN REVERSING...
- Author(s) : GOLDSCHMIDT V. W., SCHARF R. R. R., WHITE L.
- Date : 1984
- Languages : English
View record
-
MOTOR CURRENT SIGNATURE ANALYSIS. A POTENTIAL D...
- Author(s) : MILLER W. A.
- Date : 1989
- Languages : English
View record
-
EFFECT OF CYCLING AND FROST FORMATION ON HEAT P...
- Author(s) : BITTLE B. B., GOLDSCHMIDT V. W.
- Date : 1983
- Languages : English
View record
-
AN OVERVIEW OF THE FOUR-WAY REFRIGERANT REVERSI...
- Author(s) : BLACK G. D.
- Date : 1987
- Languages : English
View record
-
FROSTING EXPERIMENTS FOR A HEAT PUMP HAVING A O...
- Author(s) : MILLER W. A.
- Date : 1984
- Languages : English
View record