IIR document
Simulation of the heat exchangers of a window air conditioner retrofitted with R407C.
Author(s) : DEVOTTA S., PADALKAR A. S., SANE N. K., et al.
Summary
The paper presents the results of simulation of the heat exchangers of an HCFC-22 window air conditioner retrofitted with R407C. The simulation was carried out using EVAP-COND, a heat exchanger model developed by NIST. A typical Indian window air conditioner of capacity 5.13 kW (1.5 TR) was selected for the study. The performance of the heat exchangers with R407C is compared with the baseline performance with HCFC-22. The simulated results were validated by comparing them with the experimental results obtained using window air conditioners retrofitted with R407C. The assessment parameters considered were the temperatures of the refrigerant and the air, and pressures with pressure drop in the refrigerant flow.
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Simulation of the heat exchangers of a window air conditioner retrofitted with R407C.
- Record ID : 2004-1060
- Languages: English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Publication date: 2003/08/17
Links
See other articles from the proceedings (398)
See the conference proceedings
Indexing
-
Themes:
HCFCs;
Comfort air conditioning;
Blends - Keywords: R407C; Air conditioner; R22; Simulation; Performance
-
Experimental investigation of the performance o...
- Author(s) : KIM S. G., KIM M. S., RO S. T.
- Date : 2002/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 25 - n. 5
- Formats : PDF
View record
-
Computational comparison of R22 and R407C air c...
- Author(s) : VAISMAN I. B.
- Date : 1998/07/14
- Languages : English
- Source: Proceedings of the 1998 Purdue International Refrigeration Conference.
View record
-
Experimental investigation of the performance o...
- Author(s) : ZENG D. Q., LIN X. N.
- Date : 2004
- Languages : Chinese
- Source: Refrigeration - vol. 87 - n. 2
View record
-
Discussion on application of R407C in the room ...
- Author(s) : WU J. S.
- Date : 2003/06
- Languages : Chinese
- Source: Refrigeration - vol. 83 - n. 2
View record
-
Goede prestaties van groene airconditioner: mee...
- Author(s) : DIJKSTRA E.
- Date : 2003/02
- Languages : Dutch
- Source: Koude & Luchtbehandeling - vol. 96 - n. 2
View record