IIR document

Steady state vapor compression refrigeration cycle simulation for a monovalent inverter-driven water-to-water heat pump with a desuperheater for low energy houses.

Author(s) : BLANCO D. L., NAGANO K., MORIMOTO M.

Type of article: Article, IJR article

Summary

A steady-state simulation is presented for a monovalent inverter-driven water-to-water heat pump with a desuperheater. For design-oriented simulations, superheating or subcooling degrees are used as input. However, the proposed simulation only uses the system's refrigerant charge, environmental, and control parameters, which make it particularly useful for off-design evaluations, including the annual performance factor calculation. Block models were used for the compressor and electronic expansion valve, while novel adaptive zone models were used for the heat exchangers. A multivariable error minimization algorithm was used over a sequential component scheme to provide global convergence. The numerical calculations were compared with 118 experimental results. The resulting COP agrees within 10% for 95.77% of the data. The mapping results reveal a maximum COP deviation of 8.78%. Computational results for the studied system reveal that a constant degree of superheating might not always maximize the COP.

Available documents

Format PDF

Pages: 1833-1847

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Steady state vapor compression refrigeration cycle simulation for a monovalent inverter-driven water-to-water heat pump with a desuperheater for low energy houses.
  • Record ID : 30005895
  • Languages: English
  • Subject: Environment
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 7
  • Publication date: 2012/11