Studies on thermal characteristics of ice storage tank. 2. Thermal response of ice-on-coil type storage tank in which the coil is partially located.
[In Japanese. / En japonais.]
Author(s) : NAKAHARA N., FUKUNAGA K., YAMAHA M.
Type of article: Article
Summary
The coil was installed in 5 locations, at the outlet side, center, inlet side, lower part and upper part of the tank. Then experiments on connected tanks were carried out. For ice-making process, the effect of agitation and coil location was examined. The agitation, for any agitation rate examined, was effective to decrease ice-making time at any locations. Temperature stratification appeared in case without agitation. For ice-making process, the dominant factor for thermal response is the Archimedes number at the inlet. For center coil location considered to be the best, effect of the standardized inlet heat flux and Archimedes number was examined. The difference of thermal response between the single tank experiments and the connected tank experiments was hardly found. Regressive equations based on the results have been proposed to predict ice storage performance.
Details
- Original title: [In Japanese. / En japonais.]
- Record ID : 1992-3033
- Languages: Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 48
- Publication date: 1991/02
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (5)
See the source
Indexing
-
ACCUMULATION OF COLD IN ICE BANK TANKS.
- Author(s) : CERMAK J.
- Date : 1982
- Languages : Czech
- Source: Potravin. Chladici Tech. - vol. 13 - n. 6
View record
-
Energy management of ice packs with vaporising ...
- Author(s) : WIJBENGA J.
- Date : 1991/08
- Languages : Dutch
- Source: Koude Mag. - vol. 3 - n. 7-8
View record
-
Parametric analysis of an internal-melt ice-on-...
- Author(s) : NETO J. H. M., KRARTI M.
- Date : 1997
- Languages : English
- Source: ASHRAE Transactions.1997 Annual Meeting, Boston, MA.
View record
-
The study of air-cooled chiller's performance u...
- Author(s) : YANG Z.
- Date : 1997/09/09
- Languages : English
- Source: International Symposium on Air Conditioning in High Rise Buildings - 1997
- Formats : PDF
View record
-
Influence of the wall surface roughness on the ...
- Author(s) : ERNST G., KAUFFELD M.
- Date : 2016/05/18
- Languages : English
- Source: 11th IIR Conference on Phase-Change Materials and Slurries for Refrigeration and Air Conditioning. Proceedings: Karlsruhe, Germany, May 18-20, 2016.
- Formats : PDF
View record