Study on the materials used to manufacture compressors and reliability of the refrigeration circuit in a refrigerator using R134a refrigerant.

[In Japanese. / En japonais.]

Author(s) : KOMATSUBARA T., SUNAGA T., TAKAHASI Y.

Type of article: Article

Summary

Polyolester oils were selected for use with R134a because of their miscibility. The authors found sludge deposition in capillary tubes after life tests of the refrigerator with polyolester (POE) and detected metal soap, decomposed oil and alkaline ions by analysis of sludge. They improved the stability and lubricity of POE and reevaluated process materials and contaminations in refrigerating circuit. The paper discussed these newly developed technologies and the evaluation results in terms of life test of refrigerator.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 2003-2261
  • Languages: Japanese
  • Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 19 - n. 4
  • Publication date: 2002
  • Document available for consultation in the library of the IIR headquarters only.