Study on the practical design method of the chain-like connected closed-type thermal storage tanks considering operating experience.
[In Japanese. / En japonais.]
Author(s) : NAKAHARA T., IMAIIDA T., HUJIWARA M., TANIGUCHI H., KUDO K.
Type of article: Article
Summary
A practical design method on chain-like connected closed-type thermal storage tanks with capacities of 120 m3, was clarified as follows: 1) the combination of two perforated plates are installed at the top and the bottom of every storage tank as a rectifier to obtain uniform velocity distribution. Pressure drop at each perforated plate sets the same value as dynamic pressure of the upper stream. The rectifier indicates very high performance of uniformity; 2) the amount of the mixing volume in the storage tank is found using the behaviour of temperature response of the tank with a stepwise change of inlet; 3) the Archimedean number is kept larger than 0.5 to get the mixing volume down to less than 10% of the tank volume. A 0.1 number gives the minimum tank wall volume, which is most economical point.
Details
- Original title: [In Japanese. / En japonais.]
- Record ID : 1994-1800
- Languages: Japanese
- Source: Trans. JAR - vol. 10 - n. 2
- Publication date: 1993
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (19)
See the source
Indexing
- Themes: Thermal energy storage
- Keywords: Operation; Design; Tank; Water; Thermal energy storage
-
Thermally stratified chilled water (TES) for en...
- Author(s) : ANDREPONT J. S., CHUAN K., SANJUAN M., WINTER P. J.
- Date : 1996/09
- Languages : English
- Source: AIRAH J. - vol. 50 - n. 9
View record
-
Un stockage d'eau glacée économise une centrale.
- Author(s) : TRANCART M.
- Date : 1997/07
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 848
View record
-
Buffer tank maintains water temperature in refr...
- Author(s) : WESSELINGH N.
- Date : 1992/11
- Languages : Dutch
- Source: Koude Mag. - n. 11
View record
-
A perturbation model for stratified thermal ene...
- Author(s) : VOTYAKOV E. V., BONANOS A. M.
- Date : 2014/08
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 75
View record
-
Performance test on thermal energy storage tank...
- Author(s) : FUKAI J., HAMADA Y., MOROZUMI Y., et al.
- Date : 2004/07
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 94
View record