Summary
The air conditioning system often works under part load condition, it causes low energy efficiency and raises unnecessary energy consumption. Frequency conversion operation is a popular way to save energy. The frequency conversion range of cooling water pump is influenced by the load of water chilling unit, cooling tower and the chilling water. It is instructional to study frequency conversion range for the least energy consumption of air conditioning system according to the operating characteristic. Theoretic model of water chilling unit, cooling water pump and cooling tower is set up in this paper. The frequency conversion operating characteristic of cooling water pump under certain cooling load and outdoor meteorology parameter is obtained.
Available documents
Format PDF
Pages: ICR07-E1-467
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: The characteristic analysis of chilling water unit energy-saving operation by frequency conversion.
- Record ID : 2008-0345
- Languages: English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Publication date: 2007/08/21
Links
See other articles from the proceedings (839)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Energy consumption; Comparison; Variable speed; Cooling tower; Chiller; Pump; Modelling; Air conditioning; Compressor
-
Energy use and economic comparison of chilled-w...
- Author(s) : BAHNFLETH W. P., PEYER E. B.
- Date : 2006/06/25
- Languages : English
- Source: ASHRAE Transactions. 2006 Annual Meeting, Quebec City, Canada. Volume 112, part 2 + CD-ROM.
View record
-
Research on energy consumption of variable-freq...
- Author(s) : WANG H. D.
- Date : 2003/04/22
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
View record
-
Air-conditioning water chiller with variable sp...
- Author(s) : MINEA V.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Energy conservation effect of heat source syste...
- Author(s) : UEDA K., HASEGAWA Y., SEKI W., et al.
- Date : 2008/05/20
- Languages : English
- Source: 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
View record
-
MODELS FOR VARIABLE-SPEED CENTRIFUGAL CHILLERS.
- Author(s) : BRAUN J. E., MITCHELL J. W., KLEIN S. A.
- Date : 1987
- Languages : English
View record