Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate.
Author(s) : IRSHAD K., HABIB K., BASRAWI F., et al.
Type of article: Article
Summary
This paper examined the performance of a thermo-electric air duct system (TE-AD), which employs the thermo-electric module (TEMs) inside an air duct for providing thermal comfort in Malaysian environment. Twenty human subjects were exposed to test room equipped with TE-AD system operating at six different input current supply from 2 A to 7 A. Both objective and subjective measurements were carried out. Results show that with the increment of input current supply to the TE-AD system, subject's thermal response related to indoor condition of test room shifted from warm to neutral. Optimum performance of the TE-AD system was obtained at the input current supply of 6 A, more than 80% of subjects responded in the range of ±1 and meets ASHARE standards of acceptability criteria. Further increase in input current supply deteriorates the cooling performance of the TE-AD system. Economic comparison of the TE-AD system with the existing air conditioning system shows that economic saving of US$ 127.34/year can be achieved with additional benefits of Freon free, convenient installation, no moving part and reliable operation.
Details
- Original title: Thermal comfort study of a building equipped with thermoelectric air duct system for tropical climate.
- Record ID : 30017196
- Languages: English
- Source: Applied Thermal Engineering - vol. 91
- Publication date: 2015/12/05
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2015.08.077
Links
See other articles in this issue (57)
See the source
Indexing
- Themes: Comfort air conditioning
- Keywords: Economy; Building; Thermoelectricity; Air; Duct; Thermal comfort
-
Air conditioning system of DN tower 21 (Daiichi...
- Author(s) : NAGOYA H.
- Date : 1998/11
- Languages : Japanese
- Source: SHASE - vol. 72 - n. 11
View record
-
THE THERMAL ENVIRONMENT AND LEVEL OF AROUSAL: F...
- Author(s) : PURCELL A. T., THORNE R. H.
- Date : 1987
- Languages : English
- Source: Archit. Sci. Rev. - vol. 30 - n. 4
View record
-
EXPERIMENTAL ESTIMATION OF PERSONAL AIR CONDITI...
- Author(s) : TANAGO H., TAKEDA M.
- Date : 1991
- Languages : Japanese
- Source: SHASE - vol. 65 - n. 7
View record
-
A questionnaire for studies of sick building sy...
- Author(s) : RAW G. J.
- Date : 1995
- Languages : English
- Source: BRE Rep. - BR 287; 9 p.; 3 tabl.; 8 ref.
View record
-
DISSATISFACTION WITH AIR CONDITIONING: COMPARIN...
- Author(s) : HLADKY A., BAKALAR V.
- Date : 1986
- Languages : Czech
- Source: Zdrav. Tech. Vzduchotech. - vol. 29 - n. 1
View record