Summary
Sets up a thermodynamic model based on mechanical draft counterflow cooling tower with the fully consideration of Lewis number and the change of characteristic number. Verifies accuracy and reliability of the model with a subway station in Guangzhou as test object, and analyses the influence of Lewis number and correction coefficient of characteristic number on cooling tower. The results show that the relative errors of outlet water temperature and inlet air enthalpy are below 2% and 3%, respectively. For large temperature difference, using Lewis relation can result in a large deviation between the simulated and the experimental results, especially for large difference between the dry-bulb temperature of inlet air into tower and the temperature of inlet water. The relative errors of the outlet air temperature and the relative humidity can reach 16.7% and 10.7%, respectively. The more the actual characteristic number deviates from the standard condition value, the greater the impact on performance of cooling tower is.
Available documents
Format PDF
Pages: 90-95, 89
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30013696
- Languages: Chinese
- Source: HV & AC - vol. 44 - n. 293
- Publication date: 2014/08
Links
See other articles in this issue (2)
See the source
Indexing
- Themes: Evaporators, condensers and other heat exchangers
- Keywords: Thermodynamics; Cooling tower; Temperature; Performance; Model; Counterflow
-
Study of a counterflow wet cooling tower. I. Si...
- Author(s) : IOSIFESCU C., TOFAN S.
- Date : 2012
- Languages : English
- Source: Buletinul Institutului politehnic din Iasi, Sectia Constructii de Masini - vol. 58 - n. 3
View record
-
Performance of counterflow cooling towers with ...
- Author(s) : KRANC S. C.
- Date : 1993
- Languages : English
- Source: Numer. Heat Transf., A - vol. 23 - n. 1
View record
-
Experimental investigation of the performance c...
- Author(s) : LEMOUARI M., BOUMAZA M.
- Date : 2010/10
- Languages : English
- Source: International Journal of thermal Sciences - vol. 49 - n. 10
View record
-
Performance characteristics of a trickle fill i...
- Author(s) : GROBBELAAR C. J., REUTER H. C. R., BERTRAND T. P.
- Date : 2013/01
- Languages : English
- Source: Applied Thermal Engineering - vol. 50 - n. 1
View record
-
Calculations on performance characteristics of ...
- Author(s) : ZHANG Q., WU J., ZHANG G., et al.
- Date : 2012/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 2
- Formats : PDF
View record