Two-stage high frequency pulse tube cooler for refrigeration at 25 K.
Author(s) : DIETRICH M., THUMMES G.
Type of article: Article
Summary
A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first-stage, since the intended application requires no cooling power at this intermediate temperature. Simulations where done using Sage-software to find optimum operating conditions and cold head geometry. Flow-impedance matching was required to connect the compressor designed for 60 Hz operation to the 40 Hz cold head. A cooling power of 12.9 W at 25 K with an electrical input power of 4.6 kW has been achieved up to now. The lowest temperature reached is 13.7 K. [Reprinted with permission from Elsevier. Copyright, 2010].
Details
- Original title: Two-stage high frequency pulse tube cooler for refrigeration at 25 K.
- Record ID : 2010-1012
- Languages: English
- Source: Cryogenics - vol. 50 - n. 4
- Publication date: 2010/04
- DOI: http://dx.doi.org/10.1016/j.cryogenics.2010.01.010
Links
See other articles in this issue (3)
See the source
Indexing
-
Multi-objective optimization of a stirling-type...
- Author(s) : JAFARI S., MOHAMMADI B., BOROUJERDI A. A.
- Date : 2013/05
- Languages : English
- Source: Cryogenics - vol. 55-56
View record
-
A REVIEW OF PULSE TUBE REFRIGERATION.
- Author(s) : RADEBAUGH R.
- Date : 1990
- Languages : English
- Source: Adv. cryog. Eng. - vol. 35 B
View record
-
Impedance magnitude optimization of the regener...
- Author(s) : CAO Q., QIU L. M., ZHI X. Q., et al.
- Date : 2013/12
- Languages : English
- Source: Cryogenics - vol. 58
View record
-
Analysis and comparison of different phase shif...
- Author(s) : LEI T., PFOTENHAUER J. M., ZHOU W.
- Date : 2016/09
- Languages : English
- Source: Cryogenics - vol. 80
View record
-
Etude paramétrique comparée des performances de...
- Author(s) : NIKA P.
- Date : 1999/02
- Languages : French
- Source: Int. J. therm. Sci. - Rev. gén. Therm. - vol. 38 - n. 2
View record