IIR document
Using district heating networks for air conditioning.
Author(s) : SCHWEIGLER C., RIESCH P., ALEFELD G.
Summary
Currently available absorption machinery for air conditioning has limited application in district heating networks. Standard, single-stage absorption machines are driven with heat of at least 80 deg C. An advanced cycle which can use heat down to temperatures of about 55 deg C and permits temperature glides in generation by more than 30 K has been identified. Depending on the estimated heat exchanger area, competitive machine costs for this new chiller can be expected. Two prototypes of the new cycle, each with a cooling capacity of about 400 kilowatts, will be tested in district heating networks. The project is financed by a consortium of utilities and the German Ministry of Science and Technology.
Available documents
Format PDF
Pages: 865-872
This document is to be digitised and will be available within 10 working days
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Using district heating networks for air conditioning.
- Record ID : 1996-1778
- Languages: English
- Source: For a Better Quality of Life. 19th International Congress of Refrigeration.
- Publication date: 1995/08/20
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (488)
See the conference proceedings
-
Economic assessment of low firing temperature a...
- Author(s) : GOODHEART K. A., KLEIN S. A., SCHULTZ K.
- Date : 2002/01/12
- Languages : English
- Source: ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
View record
-
Ammoniac et absorption pour l'Exposition univer...
- Author(s) : VRINAT G.
- Date : 1998/06
- Languages : French
- Source: Rev. gén. Froid - vol. 88 - n. 984
View record
-
A heat-recovery cooling system to conserve ener...
- Author(s) : NASSER A. E. M., KALAY M. A. el-
- Date : 1991
- Languages : English
- Source: Appl. Energy - vol. 38 - n. 2
View record
-
Combined heating and refrigeration: combined he...
- Author(s) : FRITZ B.
- Date : 1992/12
- Languages : German
- Source: Klima Kälte Heiz. - vol. 20 - n. 12
View record
-
The influence of flue gas temperature on LiBr-H...
- Author(s) : JIN S. M., ZHU Y. C., WU W. B.
- Date : 2008/04/05
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR'2008.
View record