IIR document

Validation of a multi-circuit heat exchanger model for evaluating the effect of refrigerant circuitry on cross-fin conduction in evaporator mode.

Author(s) : SALEEM S., BRADSHAW C. R., BACH C. K.

Type of article: IJR article

Summary

Fin-and-tube heat exchangers can have active circuits directly adjacent to inactive circuits at part load conditions, leading to cross-fin conduction. Cross-fin conduction needs to be accounted for in heat exchanger modelling to accurately predict heat exchanger performance. This study explores how refrigerant circuitry can influence cross-fin conduction in multi-circuit evaporator coils. Our advanced segment-by-segment heat exchanger model is validated against two-phase refrigerant data obtained from our experimental facility. Three, custom designed, multi-circuit fin-and-tube heat exchanger coils with distinct circuities were used for validation purposes, including an interleaved, vertical and block circuited coils, respectively. A total of 162 experiments with several refrigerant and air inlet conditions, at full load (all circuits active) and part load (some circuits active) were carried out. At full load, for all coils, differences in coil capacity between simulated and experimental capacities were no greater than 10%, for part load the differences are larger. For the test coil with interleaved circuitry, operating with 3 of 8 circuits active, the mean average percentage error (MAPE) between experimental and simulated capacity was 2.7% when cross-fin conduction was considered, increasing to 7.7% when it was ignored. Similarly, for test coil with block circuitry, operating with 2 out of 4 circuits active, the MAPE between experimental and simulated capacity was 1.7% when cross-fin conduction was considered, and 3.4% when ignored. Results suggest that the effect of cross-fin conduction on coil capacity is directly proportional to number of inactive circuits, and it is more pronounced on interleaved circuitry compared to block circuitry.

Available documents

Format PDF

Pages: 623-633

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Validation of a multi-circuit heat exchanger model for evaluating the effect of refrigerant circuitry on cross-fin conduction in evaporator mode.
  • Record ID : 30029169
  • Languages: English
  • Subject: Technology
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
  • Publication date: 2021/11
  • DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.08.015
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (95)
See the source