Application of ozone technique in inactivation of microbial contamination in refrigerators.

Zastosowanie techniki ozonowania w inaktywacji mikroflory stanowiacej zanieczyszczenie urzadzen chlodniczych.

Author(s) : SZOSLAND-FALTYN A., KROLASIK J., POLAK E.

Type of article: Article

Summary

This paper presents the results of research on the microbial inactivation in refrigerators by ozonation and compared its effectiveness with ultraviolet radiation method of disinfection. The study shows that 1 h of ozonation is sufficient to achieve the reduction of microorganism by 2 logarithmic cycle for refrigeration equipment with a capacity of 100 l to 175 l and a temperature above 0°C.

Details

  • Original title: Zastosowanie techniki ozonowania w inaktywacji mikroflory stanowiacej zanieczyszczenie urzadzen chlodniczych.
  • Record ID : 30011219
  • Languages: Polish
  • Source: Chlodnictwo - vol. 48 - n. 3
  • Publication date: 2013/03