Common fault effects on a natural refrigerant, variable-speed heat pump.
Author(s) : BELLANCO I., BELIO F., VALLES M., GERBER R., SALOM J.
Type of article: IJR article
Summary
The European heat pump market is growing every year as European legislation moves towards the use of natural refrigerants that have less global warming potential than conventional refrigerants. Even though heat pumps are very efficient, the appearance of hard-to-detect faults increases energy consumption. The present study emulated some of the most common faults on a variable-speed heat pump charged with propane. The faults tested were evaporator fouling, compressor valve leakage, liquid line restriction and refrigerant overcharge. The effect of these faults on performance and several heat pump features are described. Evaporator fouling was the fault with least COP degradation and compressor valve leakage with the most (7% and 56% COP reduction, respectively). The results are compared with the results from a comparable study. The heat pump covered the demand generated by nearly all the faults at the expense of increasing the power consumption. The features of each fault are summarized in a chart, which could be used as table for diagnosing faults.
Available documents
Format PDF
Pages: 259-266
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Common fault effects on a natural refrigerant, variable-speed heat pump.
- Record ID : 30029278
- Languages: English
- Subject: Technology, HFCs alternatives
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 133
- Publication date: 2022/01
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.10.017
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (32)
See the source
Indexing
-
Themes:
Residential heat-pumps;
Hydrocarbons - Keywords: Variable speed; Heat pump; Prototype; Propane; R290; Natural refrigerant; Expérimentation; Failure; Detection; Performance; COP; Energy consumption; Low GWP
-
A propane hydronic heat pump with energy storage.
- Author(s) : SHEN B., LI Z., WAN H., GLUESENKAMP K., FRICKE B.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Coupling effects in fault detection and diagnos...
- Author(s) : LLOPIS-MENGUAL B., NAVARRO-PERIS E.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Refrigerant charge distribution in brine-to-wat...
- Author(s) : SANCHEZ MORENO GINER L., METHLER T., BARCELÓ RUESCAS F., GONZÁLVEZ-MACIÁ J.
- Date : 2023/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Formats : PDF
View record
-
Experimental results of a high efficient booste...
- Author(s) : PITARCH M., GONZÁLVEZ-MACIÁ J., NAVARRO-PERIS E., et al.
- Date : 2016/08/21
- Languages : English
- Source: 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
View record
-
Resultados experimentales de un prototipo tipo ...
- Author(s) : PITARCH MOCHOLI M., GONZÁLVEZ-MACIÁ J., NAVARRO-PERIS E., et al.
- Date : 2018/03
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - n. 511
- Formats : PDF
View record