IIR document
Comparaison de meubles frigorifiques de vente verticaux ouverts et fermés dans des environnements externes tempérés et tropicaux.
Comparing open and closed vertical refrigerated display cabinets at mild and tropical external environments.
Number: pap. n. 1296
Author(s) : HEIDINGER G. G., NASCIMENTO S. M., GASPAR P. D., et al.
Summary
This paper reports the results of experimental tests performed according to ISO 23953 in vertical open and closed refrigerated display cabinets (VORDC vs. VCRDC). Tests were performed at a mild climate class (n. º 3: T=25°C; f=60%) and a tropical one (n. º 6: T=27°C; f=70%). The direct energy consumption is 46% higher at VCRDC due to the heated glass doors frame and defrost heaters. The product simulator temperature is higher and more stable at VORDC. The highest product simulator temperature is lower (-1.4°C) at the VCRDC and less stable (+2.7°C variation) due to the opening doors period. The total mass of condensed water at the evaporator is reduced 87% and the total heat load is 77% lower at the VCRDC. Thus, the estimated total energy consumption is reduced 42%. Given the current concerns with energy consumption and sustainability of the heat exchange processes, the VCRDC provide the best solution.
Available documents
Format PDF
Pages: 9
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Comparing open and closed vertical refrigerated display cabinets at mild and tropical external environments.
- Record ID : 30026274
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.1296
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
-
Influence of operating conditions on the temper...
- Author(s) : CHAOMUANG N., FLICK D., DENIS A., et al.
- Date : 2019/07
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 103
- Formats : PDF
View record
-
Energy savings in supermarket using control the...
- Author(s) : CHAI M.-L., SHIEN Y.-T., HSIEH W. D.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Les économies d'énergie des rideaux d'air : myt...
- Date : 1996/09
- Languages : French
- Source: Chaud Froid Plomb. - vol. 50 - n. 583
View record
-
Performance optimization of a transcritical CO<...
- Author(s) : KHANLOGHI M., IZADI-ZAMANABADI R., RAMEZANI H., GULLO P.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Experimental analysis of aerothermodynamics per...
- Author(s) : NASCIMENTO S. M., HEIDINGER G. G., GASPAR P. D., et al.
- Date : 2016/07/11
- Languages : English
- Source: 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record