Compressor calorimeter experiments on R502 and R22 alternatives.
Author(s) : SHIFLETT M. B., YOKOZEKI A.
Summary
Recently, several promising candidates for replacing R502 and R22 in commercial refrigeration and residential heat pump applications have been proposed and tested. Among them, the alternatives SUVA HP62 for replacing R502 and SUVA AC9000 for replacing R22, have been found acceptable for many existing and new systems requiring little to no equipment modifications. There is, however, potential to further improve the performance of these alternatives for both existing and new equipment. Understanding the compressor characteristics of these compounds is one of the most important key factors for this purpose. The authors have performed compressor calorimeter tests for these alternatives as well as with R502 and R22. The experimental data have been analyzed with theoretical cycle calculations, and several implications of the present findings will be discussed.
Details
- Original title: Compressor calorimeter experiments on R502 and R22 alternatives.
- Record ID : 1995-0765
- Languages: English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
- Publication date: 1994/07/19
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (73)
See the conference proceedings
Indexing
-
Themes:
HCFCs;
Blends - Keywords: R502; R22; Substitute; Performance; Testing; Refrigerant
-
Laboratory evaluation and field tests of replac...
- Author(s) : LUNDQVIST P., HERBE L.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 Purdue International Refrigeration Conference.
View record
-
Results of soft-optimized system tests in ARI's...
- Author(s) : GODWIN D. S.
- Date : 1994/07/19
- Languages : English
- Source: Proceedings of the 1994 International Refrigeration Conference at Purdue.
View record
-
Assessment of HFC143a as an alternative of HCFC...
- Author(s) : BHADURI S. C.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
R290 as a substitute of R502 and R22 in commerc...
- Author(s) : LAMPUGNANI G., ZGLICZYNSKI M.
- Date : 1996/07/23
- Languages : English
- Source: Proceedings of the 1996 International Compressor Engineering Conference at Purdue.
View record
-
An alternative refrigerant to R502 for low temp...
- Author(s) : AGARWAL R., AGARWAL R. S.
- Date : 1998/03/18
- Languages : English
- Source: Emerging trends in refrigeration and air-conditioning.
- Formats : PDF
View record