Control of ammonia production in animal research facilities through ventilation system design.
Author(s) : MEMARZADEH F., MANNING A.
Summary
This paper considers the effect of air properties on ammonia levels in the cages and main room space of an animal research facility containing mouse static micro-isolators. The ammonia production from mice is affected by the level of relative humidity (RH) of the air, with higher production rates at elevated RH values. The manipulation of the room supply discharge air, therefore, offers a means of reducing ammonia levels in both the cage and room. This paper outlines a study in which the air properties are considered with regard to ammonia production both experimentally and numerically, in the latter case using the technique of airflow modelling. The paper demonstrates that even relatively modest increases in supply temperature can have major implications with regards to ammonia production, leading to the possibility that it may be possible to increase the time between cage bedding changes.
Details
- Original title: Control of ammonia production in animal research facilities through ventilation system design.
- Record ID : 2006-3132
- Languages: English
- Source: ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
- Publication date: 2005
Links
See other articles from the proceedings (23)
See the conference proceedings
Indexing
-
Air quality evaluations of animal room faciliti...
- Author(s) : TURNER W. A., MCKNIGHT F. T., JONES R. B., BARTH J. M., PAIGEN B. J., OHMAN J. L., MACDONALD M. R.
- Date : 1992
- Languages : English
- Source: ASHRAE Transactions 1992. Part 2.
View record
-
INVESTIGATING ROOM AIR FLOW IN ANIMAL LABORATOR...
- Author(s) : SODEC F., WECK F.
- Date : 1981
- Languages : German
- Source: Klima Kälte Heiz. - vol. 9 - n. 12
View record
-
Mass generation rates of ammonia, moisture, and...
- Author(s) : RISKOWSKI G. L., HARRISON P. C., MEMARZADEH F.
- Date : 2006
- Languages : English
- Source: ASHRAE Transactions. 2006 Winter Meeting. Volume 112, part 1 + CD-ROM.
View record
-
Application of natural ventilation in cattle ba...
- Author(s) : MÜLLER H. J., MÖLLER B.
- Date : 2007/06/10
- Languages : English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
View record
-
Animal facility ventilation air quality and qua...
- Author(s) : BESCH E. L.
- Date : 1992
- Languages : English
- Source: ASHRAE Transactions 1992. Part 2.
View record