CORRELATION FOR EVALUATION OF THE PERFORMANCE CHARACTERISTICS OF VAPOUR ABSORPTION REFRIGERATION CYCLES.
Author(s) : ASHA IYER P. S., SRINIVASA MURTHY S., KRISHNA MURTHY M. V.
Type of article: Article
Summary
FOUR CYCLES ARE STUDIED: A CONVENTIONAL ONE-STAGE CYCLE WITH 2 PRESSURES CORRESPONDING TO THE CONDENSER AND EVAPORATOR TEMPERATURES ; A CYCLE WITH 3 LEVELS OF PRESSURE AND A GENERATOR FUNCTIONING AT A PRESSURE SUPERIOR TO THE ONE OF THE CONDENSER ; A TWO-STAGE CYCLE WITH A RESORBER/DESORBER LOCATED BETWEEN THE EVAPORATOR AND THE ABSORBER IN A CONVENTIONAL ONE-STAGE CYCLE AND A DOUBLE EFFECT CYCLE, WITH 2 GENERATORS. THE WORKING FLUID PAIRS USED ARE R21-DMF, R22-DMF, R22-DMETEG, AMMONIA-SODIUM THIOCYANATE AND WATER-LITHIUM BROMIDE. THE COP AND THE HEAT QUANTITIES AT THE GENERATOR INLET AND AT THE ABSORBER AND CONDENSER OUTLET ARE CORRELATED WITH THE OPERATION TEMPERATURES. (Bibliogr. int. IFP-AFME-CNRS, FR., 89-230-1320.
Details
- Original title: CORRELATION FOR EVALUATION OF THE PERFORMANCE CHARACTERISTICS OF VAPOUR ABSORPTION REFRIGERATION CYCLES.
- Record ID : 1990-0118
- Languages: English
- Source: Sol. Wind Technol. - vol. 5 - n. 2
- Publication date: 1988
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (1)
See the source
Indexing
- Themes: Absorption and adsorption systems
- Keywords: Correlation; Thiocyanate; Ammonia; Absorption system; R22; R21; Sodium; Performance; COP; Water-lithium bromide; DMF; DMETEG
-
THREE PRESSURE VAPOUR ABSORPTION REFRIGERATION ...
- Author(s) : IYER P. S. A., MURTHY S. S., MURTHY M. V. K.
- Date : 1987/08/24
- Languages : English
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
Analysis of three-pressure vapour absorption re...
- Author(s) : ASHA IYER P. S., SRINIVASA MURTHY S., KRISHNA MURTHY M. V.
- Date : 1991
- Languages : English
- Source: Renew. Energy - vol. 1 - n. 1
View record
-
OPTIMIZATION OF GENERATOR TEMPERATURES IN TWO-S...
- Author(s) : SIDDIQUI M. A., RIAZ M. S.
- Date : 1991/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 14 - n. 3
- Formats : PDF
View record
-
WORKING MIXTURES FOR ABSORPTION MACHINES.
- Author(s) : GOMEZ M. L.
- Date : 1986
- Languages : Spanish
- Source: Téc. Frio Calor - vol. 35 - n. 369
View record
-
OPTIMAL COOLING AND HEATING PERFORMANCE COEFFIC...
- Author(s) : ALTAMUSH SIDDIQUI M.
- Date : 1991
- Languages : English
- Source: Energy Conversion and Management - vol. 31 - n. 1
View record