DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP1.

Author(s) : LEE R., DEVOTTA S., HOLLAND F. A.

Type of article: Article

Summary

THE THEORETICAL RANKINE POWER CYCLE EFFICIENCIES AND THE PRESSURE RATIOS HAVE BEEN PRESENTED FOR RANKINE POWER CYCLES OPERATING ON PP1 (PERFLUORO-N-HEXANE). THESE VALUES ARE LISTED FOR TEMPERATURE DROPS OF 10-75 K AND FOR BOILER TEMPERATURES 318-433 K (45-160 DEG C) IN 5 K INCREMENTS. A COMPOSITE GRAPH ILLUSTRATES THE FEASIBLE OPERATING RANGE FOR PP1 POWER CYCLE SYSTEMS. THE DERIVED THERMODYNAMIC DATA CAN BE USED FOR THE RAPID PRELIMINARY DESIGN OF RANKINE POWER CYCLE SYSTEMS OPERATING ON PP1.

Details

  • Original title: DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP1.
  • Record ID : 1984-1358
  • Languages: English
  • Source: J. Heat Recov. Syst. - vol. 3 - n. 3
  • Publication date: 1983