Summary
Integrated Part Load Value (IPLV) has been adopted worldwide as a simple metric for regulating and evaluating chiller performance. There is no exception for Hong Kong. However, the weighting factors and working temperatures for the derivation of IPLV were developed for the US. They may not be appropriate for use in other countries/regions with different operating conditions. Europe and China therefore have developed their own formula but the formulation is based on simulations and details cannot be found in literature. This study adopts a carefully-designed methodology to develop a Hong Kong specific IPLV. The development was based on actual operating characteristics of 20 Grade A office buildings in Hong Kong. Representativeness of the 20 office buildings was verified by statistical analysis. Through in-situ measurements and site surveys, hour-by-hour operating data of the studied buildings were collected. Monte Carlo analysis and ASHRAE's bin method were employed to examine the massive volume of operating data. Regression analysis was employed to formulate the Hong Kong specific IPLV. The formulated IPLV was validated. It gives the highest weighting to 75% capacity (0.682), followed in descending order are 50% capacity (0.257), 25% capacity (0.049) and 100% capacity (0.012). In determining the working temperatures, a mathematical model to enable quick estimation of entering condenser water temperature for water-cooled chillers was developed. The results and methodology adopted in this study will be useful for reference of manufacturers, policy makers and researchers in searching for a reliable metric for performance evaluation of chillers should simulation is not practical.
Available documents
Format PDF
Pages: 139-152
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Developing an integrated part load value for chillers of office buildings in Hong Kong.
- Record ID : 30028705
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 129
- Publication date: 2021/09
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.04.029
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (32)
See the source
Indexing
-
Themes:
Chillers;
Energy efficiency, energy savings - Keywords: Chiller; Office; Building; Part load; Performance; Temperature; Hong Kong; Standard; Energy efficiency; COP; Case study
-
Measurement and verification for performance co...
- Author(s) : FONG K. F., FONG M. L., CHOW T. T.
- Date : 2009/05/20
- Languages : English
- Source: ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
View record
-
Thermal performance lines of chiller plants of ...
- Author(s) : YIK F. W. H., BURNETT J., CHANG H. L.
- Date : 1995
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 16 - n. 4
View record
-
Hong Kong feels the heat.
- Author(s) : SO A.
- Date : 2006/02
- Languages : English
- Source: Build. Serv. J. - vol. 28 - n. 2
View record
-
Speed-controlled compact screw compressors with...
- Author(s) : REICHLE M., PFAFFL J.
- Date : 2017/07/20
- Languages : English
- Source: 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
View record
-
Optimizing chiller plant control logic.
- Author(s) : CHAN C. W. H.
- Date : 2006/07
- Languages : English
- Source: ASHRAE Journal - vol. 48 - n. 7
View record