Dryout quality and post-dry out heat transfer coefficient for a refrigerant flowing in horizontal evaporator tubes.
Author(s) : MORI H., YOSHIDA S., OHISHI K., et al.
Summary
Experiments were made to measure the dry out quality and the local heat transfer coefficient in the post-"dryout" region for the flow of boiling refrigerant HFC-134a inside a horizontal smooth tube and a spirally grooved (micro-fin) tube. At given conditions, dry out proceeded over a certain range quality. In the post-dry out region, the local heat transfer coefficient in the smooth tube at high mass velocity was found to be lower compared with a superheated vapour when for the grooved tube there is practically no change. According to the quality, heat transfer coefficient begins to decrease and there, stops decreasing. These qualities were clarified for both smooth tube and enhanced surface tube.
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Dryout quality and post-dry out heat transfer coefficient for a refrigerant flowing in horizontal evaporator tubes.
- Record ID : 2000-1242
- Languages: English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Publication date: 1999/09/19
Links
See other articles from the proceedings (447)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Mass transfer - Keywords: R134a; Horizontal tube; Extended surface; Mass transfer; Heat transfer; Bare pipe; Refrigerant; Boiling
-
Nucleate boiling performance of R22, R123, R134...
- Author(s) : WANG C. C., SHIEH W. Y., CHANG Y. J.
- Date : 1998
- Languages : English
- Source: ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.
View record
-
Ebullition convective d'un mélange non azéotrop...
- Author(s) : BRANESCU C., HABERSCHILL P., LALLEMAND M.
- Date : 1999/09/19
- Languages : French
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
A comparison of R22, R134a, R410A, and R407C co...
- Author(s) : ECKELS S. J., TESENE B. A.
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Annual Meeting, Seattle, Washington + CD-ROM.
View record
-
Review of available correlations for prediction...
- Author(s) : DARABI J., SALEHI M., SAEEDI M. H., OHADI M. M.
- Date : 1995/01
- Languages : English
- Source: ASHRAE Transactions.
View record
-
Condensation heat transfer of R22 and R410A in ...
- Author(s) : KIM M. H., SHIN J. S., LIM B. H.
- Date : 2002/08/26
- Languages : English
- Formats : PDF
View record