Effect of defrost frequency of defrost efficiency, defrost heat load and coolstore performance.
Efectos de la frecuencia de desescarche: eficiencia y carga térmica del desescarche, y rendimiento del almacén refrigerado.
Author(s) : SUJAU M., BRONLUND J. E., MERTS I., et al.
Type of article: Article
Summary
This article is the Spanish translation of a paper presented at the IIR meeting in Auckland, New Zealand (see this issue of the Bulletin, reference 2010-1974). The performance of a small walk-in cool store and its refrigeration system with temperature terminated electric defrost was measured for defrost intervals ranging from 6 to 30 hours for two dfifferent heat load regimes. Defrost efficiency and defrost duration were both proportional to defrost interval and approximately doubled as defrost interval increased from 6 to 30 hours. The main benefit of longer intervals arose from reduced heating of the coil mass. The change in overall system energy use with defrost interval was not significant because the system used EPR temperature control, and the latent and hence defrost heat loads were quite small compared with the total heat load. At short defrost intervals, cool store temperature control was poorer due to the pulldowns after each defrost. At long defrost intervals, cool store RH was lower and temperature control was poorer due to significant coil performance decline and longer duration defrosts. For the system and heat load conditions studied, a defrost frequency of 8 to 12 hours appeared optimal.
Available documents
Format PDF
Pages: pp. 32-40 (8 p.)
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Efectos de la frecuencia de desescarche: eficiencia y carga térmica del desescarche, y rendimiento del almacén refrigerado.
- Record ID : 2010-1975
- Languages: Spanish
- Source: IIF-IIR/Frío Calor Aire acond. - vol. 35 - n. 398
- Publication date: 2007/12
Links
- See translations: Effect of defrost frequency of defrost efficiency, defrost heat load and coolstore performance.
See other articles in this issue (4)
See the source
-
Effect of defrost frequency of defrost efficien...
- Author(s) : SUJAU M., BRONLUND J. E., MERTS I., et al.
- Date : 2006/02/16
- Languages : English
- Source: Innovative Equipment and Systems for Comfort and Food Preservation.
- Formats : PDF
View record
-
GESTION DES STOCKS EN ENTREPOSAGE FRIGORIFIQUE.
- Author(s) : GAC A.
- Date : 1982/05
- Languages : French
- Source: Rev. gén. Froid - vol. 72 - n. 5
View record
-
POSSIBILITE DE LIMITER LE BILAN FRIGORIFIQUE : ...
- Author(s) : MLYNARCZYK J., HAWLIK P.
- Date : 1987/08/24
- Languages : French
- Source: Development in refrigeration, refrigeration for development. Proceedings of the XVIIth international Congress of Refrigeration.
- Formats : PDF
View record
-
Literature survey on recommended procedures for...
- Author(s) : CRAWFORD R. R., MAVEC J. P., COLE R. A.
- Date : 1992
- Languages : English
View record
-
Economic analysis of foundation heat gain for r...
- Author(s) : CHUANGCHID P., KRARTI M.
- Date : 2000/06/24
- Languages : English
- Source: ASHRAE Transactions. 2000 ASHRAE Annual Meeting, Minneapolis, Minnesota + CD-ROM.