Summary
An accumulator heat exchanger (AHX) consists of an accumulator and an inner heat exchanger (IHX) contained in a shell. The AHX has been used in multi-air-conditioners to obtain system reliability and high performance by providing liquid refrigerant into expansion devices and preventing wet-compression. Energy is exchanged between the evaporator exit and the condenser exit in the AHX. In this study, the heat transfer characteristics of the AHX were investigated experimentally, and the effects of the AHX on the performance of a refrigeration system using R22 were measured. The operating characteristics of the refrigeration system with the AHX were considerably different from those without the AHX. The AHX system showed higher refrigerant flow rate than the non-AHX system at a constant EEV (electronic expansion valve) opening because of higher subcooling, resulting in better performance and reliability of the refrigeration system. At 50% EEV opening, the cooling capacity and COP of the AHX system were higher than those of the non-AHX system by 7.5% and 3.2%, respectively.
Available documents
Format PDF
Pages: 282-289
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Effects of accumulator heat exchangers on the performance of a refrigeration system.
- Record ID : 2007-0059
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 2
- Publication date: 2007/03
Links
See other articles in this issue (17)
See the source
Indexing
- Themes: HCFCs
- Keywords: Refrigerating system; R22; Subcooling; Performance; Expérimentation; Air conditioning; Heat exchanger
-
Characteristics of an air-conditioning system w...
- Author(s) : GOTO M., TANIFUJI K., FUJITA M., et al.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record
-
Theoretical and experimental studies on the inf...
- Author(s) : DRUGHEAN L., NICHITA M. T., NEGRU?IU C., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Experimental investigation on pressure drop of ...
- Author(s) : ZHANG H., LI J., WANG B.
- Date : 2007/06
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 28 - n. 3
- Formats : PDF
View record
-
Performance assessment of HCFC-22 window air co...
- Author(s) : DEVOTTA S., PADALKAR A. S., SANE N. K.
- Date : 2005/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 25 - n. 17-18
View record
-
Compressor response and heat transfer character...
- Author(s) : AGARWAL K. N., KUMAR R., KAUSHIK M.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record