IIR document
Assessment of R-438A as a retrofit refrigerant for R-22 in direct expansion water chiller.
Author(s) : ELGENDY E., HASSANAIN M., FATOUH M.
Type of article: Article, IJR article
Summary
The present work aims to evaluate the performance characteristics of a vapor compression refrigeration system using R-438A as a retrofit refrigerant for R-22. In order to achieve this objective, a test facility is developed and experiments are performed over a wide range of chilled water inlet temperature (11:20 °C), condenser water inlet temperature (25:35 °C) and condenser water mass flow rate (363:543 kg h-1). Results showed that as the chilled water inlet temperature changes from 11.5 to 20.5 °C, system COP increases from 1.78 to 2.07 at constant condenser water inlet temperature of 25.5 °C. Cooling capacity and COP of the system using R-438A are lower than R-22 by 11% and 12.5%, respectively. However, compressor discharge temperature using R-438A is slightly lower than R-22 which confirms that R-438A can be used as a retrofit refrigerant for R-22 to complete the remaining life time of the existing plants.
Available documents
Format PDF
Pages: 127-136
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Assessment of R-438A as a retrofit refrigerant for R-22 in direct expansion water chiller.
- Record ID : 30013122
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 50
- Publication date: 2015/02
Links
See other articles in this issue (20)
See the source
Indexing
-
Themes:
Compression systems;
HCFCs;
HFCs;
Chillers - Keywords: Refrigerating system; Direct expansion; Drop-in; Chiller; R22; Substitute; Performance; Expérimentation; Refrigerant; Air conditioning
-
Replacement of HCFC-22 refrigerant with a drop-...
- Author(s) : LLOPIS R., CABELLO R., SÁNCHEZ D., et al.
- Date : 2012/02/22
- Languages : English
- Source: CYTEF 2012. VI Congreso Ibérico y IV Congreso Iberoamericano de Ciencias y Técnicas del Frío, Madrid, España, 22-24 de febrero, 2012.
- Formats : PDF
View record
-
Exergetic analysis of R22 substitution.
- Author(s) : APREA C., GRECO A.
- Date : 2002/09
- Languages : English
- Source: Applied Thermal Engineering - vol. 22 - n. 13
View record
-
Problems of HCFC refrigerant replacement using ...
- Author(s) : CABELLO R., NAVARRO J., TORRELLA E., et al.
- Date : 2001/08/29
- Languages : English
- Source: Refrigerant Management and Destruction Technologies of CFCs.
- Formats : PDF
View record
-
Compressor response and heat transfer character...
- Author(s) : AGARWAL K. N., KUMAR R., KAUSHIK M.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record
-
Strategy of new refrigerant use and experience ...
- Author(s) : NEDOMA R.
- Date : 1999
- Languages : Czech
- Source: Vytápení Vetrání Instalace - vol. 8 - n. 3
View record