IIR document

Electrical properties of CFC and HCFC substitutes.

Author(s) : MEURER C., PIETSCH G., HAACKE M.

Type of article: Article, IJR article

Summary

Electrical properties of refrigerants are of importance as soon as bushings are surrounded by a refrigerant. This is the case e.g. for hermetic sealed motor compressors as well as for some control devices such as liquid level control units or capacity controls for compressors. This paper presents a survey of existing data for HFC refrigerants and presents new measurements for those HFC blends that have been identified as long term replacements for CFCs and HCFCs. The data collection includes permittivity, electrical conductivity and breakdown voltage. Values are given for the HFC blends R404A, R407C, R410A and R507 as well as for R134a.

Available documents

Format PDF

Pages: 171-175

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Electrical properties of CFC and HCFC substitutes.
  • Record ID : 2001-1708
  • Languages: English
  • Subject: HFCs alternatives
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 2
  • Publication date: 2001/03

Links


See other articles in this issue (7)