Emissivity of silver and stainless steel from 80 K to 300 K: application to ITER thermal shields.
Author(s) : WOODS S. I., JUNG T. M., SEARS D. R., et al.
Type of article: Article
Summary
The emissivities of thermal shield mock-up samples for ITER have been measured at sample temperatures between 80 K and 300 K using an optical method employing a primary standard broadband detector. These thermal shields, made from SS304L stainless steel coated with silver, are designed to operate at 80 K, protecting the superconducting magnet system of the ITER reactor from higher temperature regions. Our results show that the silver coating of the thermal shields can have an emissivity as low as 0.0035 at 80 K, approximately ten times lower than the emissivity of the bare polished stainless steel plate. We demonstrate that the emissivity of different regions of a thermal shield assembly can be determined in a single measurement cycle, providing further emissivity data on the insulating spacer used to separate shield plates as well as emissivity data on a silver coating repair method. The temperature dependence of the emissivity for the silver coating agrees well with a theoretical estimate based on the Drude model including phonon and surface-assisted scattering.
Details
- Original title: Emissivity of silver and stainless steel from 80 K to 300 K: application to ITER thermal shields.
- Record ID : 30011538
- Languages: English
- Source: Cryogenics - vol. 60
- Publication date: 2014/03
- DOI: http://dx.doi.org/10.1016/j.cryogenics.2014.01.002
Links
See other articles in this issue (7)
See the source
Indexing
- Themes: Cryogenics safety, instrumentation and metrology
- Keywords: Radiation; Silver; Measurement; Thermometry; Emissivity; Cryogenics; Stainless steel
-
HEAT TRANSFER IN VESSELS AND PIPING.
- Author(s) : ESCOE A. K.
- Date : 1983
- Languages : English
- Source: Hydrocarbon Processing - vol. 62 - n. 1
View record
-
Critical stress on strain increase under consta...
- Author(s) : TSUKAMOTO M., TOYODA M., MATSUMOTO T., SATOH H., WADAYAMA Y.
- Date : 1994
- Languages : Japanese
- Source: Cryogenics/ Cryog. Eng. - vol. 29 - n. 5
View record
-
Thermal conductance of pressed bimetallic conta...
- Author(s) : KITTEL P., SALERNO L. J., SPIVAK A. L.
- Date : 1994/06/07
- Languages : English
- Source: Proceedings of the 15th international cryogenic engineering conference. ICEC 15.
View record
-
Standardization of low-cycle fatigue testing me...
- Author(s) : SUZUKI K.
- Date : 1994
- Languages : Japanese
- Source: Cryogenics/ Cryog. Eng. - vol. 29 - n. 12
View record
-
Specific heat of stainless steel below 1 K.
- Author(s) : HAGMANN C., RICHARDS P. L.
- Date : 1995/05
- Languages : English
- Source: Cryogenics - vol. 35 - n. 5
View record